S2K Commerce - Products Dropdown
Actions- ${title}
Loading...
S2K Commerce - Shopping Cart
Actions- ${title}
Loading...
My Cart
Items
0
S2K Commerce - Order Entry
Actions- ${title}
Loading...
1 - 5 of 5
Description
Price
Quantity
Doug Fleenor Design DMX12DIM-ELV
Low Power, 12 Channel, ELV DMX512 Dimmer
This
dimmer uses “reverse phase” (aka: “trailing edge”) dimming techniques and MOSFET power devices. This
type of control is required for proper dimming of many LED fixtures. Each output can drive loads up to 100
Watts. Each channel may be configured for reverse phase dimming (default), forward phase dimming, or nondim operation.
The dimmer is a single-space rack mount unit with removable rack ears (included). Airflow is front to side.
Half inch holes are provided for half couplers or C clamps. The enclosure features a carry handle and a 3/8
inch safety cable slot.
The unit is ETL Listed to the UL508 standard.
SPECIFICATIONS: All specifications meet or exceed DMX512 requirements.
Input circuit: Protected EIA-485 receiver (LT1785)
Input protection: Undamaged by up to 60 Volts continuous, 15KV transients
Input signal: 0.2 volts minimum, DMX512, DMX512/1990, or DMX512-A
Input connector: Gold plated 5 pin male XLR (Neutrik D-1 series) 3 pin XLR optional
Input pass through: Gold plated 5 pin female XLR (Neutrik D-1 series) with all five pins passed through
Termination: None, unused pass through connectors must be externally terminated
Power input: 120 VAC 60 Hz 10 Amps at full load, actual current draw is 0.07A plus connected load
Power input connector: NEMA 5-15P (15A grounded parallel blade) on 18 inch 12 gauge pigtail
Idle power: 7 Watts
Power output: 120 VAC 60 Hz 0.83 Amps (100W) maximum per output
Minimum load: No minimum load requirement
Output protection: 1.5A internal fuse on each output channel
Output connectors: NEMA 5-15R (15A grounded parallel blade)
Dimming circuit: Digitally fired, optically-isolated, MOSFET power devices that allow for forward or reverse phase dimmer control
Rise/fall time: 2 uS (10% to 90% at 90 degree firing angle) at rated load
Rise/fall time: 2 uS (10% to 90% at 90 degree firing angle) at rated load
Dimming curve: Square law, visually appealing on LED lamps (120V), halogen lamps, magnetic low-voltage
(MLV) and electronic low-voltage (ELV)
Non-dim curve: Each channel can be configured as a non-dim which turns on at 60%, off at 40%
Outputs switch on at zero crossing. Other non-dim trip point options include 50% and 1%
(globally settable).
DMX footprint: Twelve consecutive DMX slots beginning with the selected DMX starting address
DMX starting address: Three digit front panel thumbwheel switch, address changes are immediate (no power cycling
required)
Local control: An “address switch” setting of 601 turns on output 1, 602 turns on output 2, etc. A setting of 699
turns on all outputs. A setting of 698 turns on all outputs when DMX is present. A setting of 697
turns on all outputs if any DMX level is above zero.
Status indicators: Red POWER indicator
Green MIMIC 1 indicator mimics the intensity of output 1 (useful in troubleshooting)
Green SIGNAL indicator illuminates when DMX512 is present and flashes when local control is
active (address switch settings of 601 thru 612 and 697 thru 699)
Cooling: Processor controlled low speed fan exchanges internal air from front to side.
Isolation: DMX512 input is optically isolated from AC power circuits to 600 Volts.
Color: Silver hammer tone with black front and rear panels.
Safety listing: ETL Listed to UL 508
Size and weight: 1.7"H × 10.5"D × 19"W (17" behind rack ears), 7 pounds, rack ears are included.
Five-year parts and labor warranty against manufacturing defects.
Item#:
DMX12DIM-ELV
Available:
Special Order/Direct Ship
Call to order
Doug Fleenor Designs DMX12DIM-ELV-JBOX
Wall Mounted, Low Power, 12 Channel, ELV DMX512 Dimmer
The dimmer is a wall mounted unit. All connections are made by terminal blocks for easy contractor installation. The NEMA1 electrical enclosure is provided with standard conduit knockouts on four surfaces.The DMX12DIM ELV-JBOX is ETL Listed to the UL508 standard.
SPECIFICATIONS: All specifications meet or exceed DMX512 requirements.
Input circuit: Protected EIA-485 receiver (LT1785)
Input protection: Undamaged by up to 60 Volts continuous, 15KV transients
Input signal: 0.2 volts minimum, DMX512, DMX512/1990, or DMX512-A
Input & thru connectors: Pluggable Phoenix terminal blocks
Termination: No internal termination provided. A 120 Ohm termination resistor is provided on the Thru
connector if the dimmer is the last device on the line
Power input: 120 VAC 60 Hz 10 Amps at full load, actual current draw is 0.07A plus connected load
Power input connector: 3 position terminal block (Line, Neutral, Ground) suitable for up to #12 AWG wire
Idle power: 7 Watts
Power output: 120 VAC 60 Hz 0.83 Amps (100W) maximum per output
Minimum load: No minimum load requirement
Output protection: 1.5A internal fuse on each output channel
Output connectors: 2 position terminal block (Line, Neutral) on each output suitable for up to #12 AWG wire
Dimming circuit: Digitally fired, optically-isolated, MOSFET power devices that allow for forward or reverse phase dimmer control
Dimming circuit: Digitally fired, optically-isolated, MOSFET power devices that allow for forward or reverse phase dimmer control
Rise/fall time: 2 uS (10% to 90% at 90 degree firing angle) at rated load
Dimming curve: Square law, visually appealing on LED lamps (120V), halogen lamps, magnetic low-voltage (MLV) and electronic low-voltage (ELV)
Non-dim curve: Each channel can be configured as a non-dim which turns on at 60%, off at 40%
Outputs switch on at zero crossing. Other non-dim trip point options include 50% and 1% (globally settable).
DMX footprint: Twelve consecutive DMX slots beginning with the selected DMX starting address
DMX starting address: Three digit thumbwheel switch, address changes are immediate (no power cycling required)
Local control: An “address switch” setting of 601 turns on output 1, 602 turns on output 2, etc. A setting of 699 turns on all outputs. A setting of 698 turns on all outputs when DMX is present. A setting of 697 turns on all outputs if any DMX level is above zero.
Status indicators: Red POWER indicator
Green MIMIC 1 indicator mimics the intensity of output 1 (useful in troubleshooting)
Green SIGNAL indicator illuminates when DMX512 is present, flashes when local control is active (address switch settings of 601 thru 612 and 697 thru 699)
Cooling: Convection cooling, no fan required
Isolation: DMX512 input is optically isolated from AC power circuits to 600 Volts
Color: Gray
Safety listing: ETL Listed to UL 508
Size and weight: 18"H × 4”D × 12"W, 10 pounds
Warranty: Five-year parts and labor warranty against manufacturing defects
Warranty: Five-year parts and labor warranty against manufacturing defects
Item#:
DMX12DIM-ELV-JBOX
Available:
Special Order/Direct Ship
Call to order
Doug Fleenor Designs DMX24DIM
Low Power, 24 Channel, DMX512 Dimmer
The dimmer is a single-space rack mount unit with removable rack ears. Airflow is front to side. Half inch holes are provided for half couplers or C clamps. The enclosure features a carry handle and a 3/8 inch safety cable slot. The unit is ETL Listed to the UL508 standard
SPECIFICATIONS: All specifications meet or exceed DMX512 requirements.
SPECIFICATIONS: All specifications meet or exceed DMX512 requirements.
Input circuit: Protected EIA-485 receiver (LT1785).
Input protection: Undamaged by up to 60 Volts continuous, 15KV transients.
Input signal: 0.2 volts minimum, 12 volts maximum, DMX512, DMX512/1990, or DMX512-A.
Input connector: Gold plated 5 pin male XLR (Neutrik D-1 series) 3 pin XLR optional.
Input pass through: Gold plated 5 pin female XLR (Neutrik D-1 series). All five pins are passed through.
Termination: None. Unused pass through connectors must be externally terminated.
Power input: 120 VAC 60 Hz 20 Amps at full load. Actual current draw is 0.05A plus connected load.
Power input connector: NEMA 5-15P (15A U-ground) on 18 inch 12 gauge pigtail. Connector must be replaced with a 20A connector for connected loads greater than 1800 Watts.
Idle power: Less than 1 Watt.
Power output: 120 VAC 60 Hz 0.83 Amps maximum per output.
Minimum load: No minimum load requirement.
Output protection: None. Overloading of outputs can result in output failure.
Output connectors: NEMA 1-15R (15A polarized ungrounded parallel blade).
Dimming circuit: Digitally fired, phase controlled 16 Amp snubberless triac (Alternistor) with high dv/dt driver. Triacs are screwdriver replaceable. One spare triac provided. A leakage control circuit on each output prevents ghosting of small loads.
Rise time: 2 uS (10% to 90% at 90 degree firing angle) at rated load.
Dimming curve: Square law. Visually appealing on LED lamps (120V), halogen lamps, magnetic low voltage (MLV) and electronic low-voltage (ELV).
Non-dim curve: Optional factory programmed non-dims turn on at 60%, off at 40% (or other user specified points). Outputs switch at zero crossing.
DMX footprint: Twenty-four consecutive DMX slots beginning with the selected DMX starting address.
DMX starting address: Three digit front panel thumbwheel switch. Address changes are immediate (no power cycling required).
Local control: “Address switch” setting of 601 turns on output 1, 602 turns on output 2, etc.
Chase mode: Factory programmed chase sequences are available. Please call.
Status indicators: Red POWER indicator.
Green MIMIC 1 indicator mimics the intensity of output 1 (useful in troubleshooting).
Green SIGNAL indicator illuminates when DMX512 is present; flashes when local control is active (address switch settings of 601 thru 624).
Cooling: Processor controlled low speed fan exchanges internal air from front to side.
Isolation: DMX512 input is optically isolated from AC power circuits to 600 Volts.
Color: Silver hammer tone with black front and rear panels.
Safety listing: ETL Listed to UL 508
Size and weight: 1.7" high x 10.5" deep x 19" wide (17" behind rack ears), 7 pounds
Warranty: Five years parts and labor. Dimmer must be returned to Doug Fleenor Design for warranty repair.
Call to order
Doug Fleenor Designs DMX24DIM-2U
Low Power, 24 Channel, DMX512 Dimmer, U-Ground Outputs
The dimmer is a two-space rack mount unit with removable rack ears. Airflow is front to side. Half inch holes are provided for half couplers or C clamps. The enclosure features a carry handle and a 3/8 inch safety cable slot. The unit is ETL Listed to the UL508 standard
SPECIFICATIONS: All specifications meet or exceed DMX512 requirements.
Input circuit: Protected EIA-485 receiver (LT1785).
Input protection: Undamaged by up to 60 Volts continuous, 15KV transients.
Input signal: 0.2 volts minimum, 12 volts maximum, DMX512, DMX512/1990, or DMX512-A.
Input connector: Gold plated 5 pin male XLR (Neutrik D-1 series) 3 pin XLR optional.
Input pass through: Gold plated 5 pin female XLR (Neutrik D-1 series). All five pins are passed through.
Termination: None. Unused pass through connectors must be externally terminated.
Power input: 120 VAC 60 Hz 20 Amps at full load. Actual current draw is 0.05A plus connected load.
Power input connector: NEMA 5-15P (15A U-ground) on 18 inch 12 gauge pigtail. Connector must be replaced with a 20A connector for connected loads greater than 1800 Watts.
Idle power: Less than 1 Watt.
Power output: 120 VAC 60 Hz 0.83 Amps maximum per output.
Minimum load: No minimum load requirement.
Output protection: None. Overloading of outputs can result in output failure.
Output connectors: NEMA 1-15R (15A polarized ungrounded parallel blade).
Dimming circuit: Digitally fired, phase controlled 16 Amp snubberless triac (Alternistor) with high dv/dt driver. Triacs are screwdriver replaceable. One spare triac provided. A leakage control circuit on each output prevents ghosting of small loads.
Rise time: 2 uS (10% to 90% at 90 degree firing angle) at rated load.
Dimming curve: Square law. Visually appealing on LED lamps (120V), halogen lamps, magnetic low voltage (MLV) and electronic low-voltage (ELV).
Non-dim curve: Optional factory programmed non-dims turn on at 60%, off at 40% (or other user specified points). Outputs switch at zero crossing.
DMX footprint: Twenty-four consecutive DMX slots beginning with the selected DMX starting address.
DMX starting address: Three digit front panel thumbwheel switch. Address changes are immediate (no power cycling required).
Local control: “Address switch” setting of 601 turns on output 1, 602 turns on output 2, etc.
Chase mode: Factory programmed chase sequences are available. Please call.
Status indicators: Red POWER indicator.
Green MIMIC 1 indicator mimics the intensity of output 1 (useful in troubleshooting).
Green SIGNAL indicator illuminates when DMX512 is present; flashes when local control is active (address switch settings of 601 thru 624).
Cooling: Processor controlled low speed fan exchanges internal air from front to side.
Isolation: DMX512 input is optically isolated from AC power circuits to 600 Volts.
Color: Silver hammer tone with black front and rear panels.
Safety listing: ETL Listed to UL 508
Size and weight: 3.5" high x 10.5" deep x 19" wide (17" behind rack ears), 10 pounds
Warranty: Five years parts and labor. Dimmer must be returned to Doug Fleenor Design for warranty repair.
Call to order
Doug Fleenor Design DMX8DIM
Low Power, 8 Channel, DMX512 Dimmer
The dimmer electronics are housed in a 12x12x4 inch NEMA Type 1 enclosure and are easily removable so the enclosure can be installed and rough wired without the electronics in place. Then, upon completion of drywall, the electronics can be reinstalled using only four screws. A protective bag is included for storing the electronics during installation. Wiring is by compression type screw terminal blocks. Rated at 250 Watts per output, the dimmer has self-resetting overload protection and is powered by a single 20A branch circuit. Features include dim/non-dim per output, local control for load testing, a troubleshooting LED, and an optically isolated DMX input. DMX512-A compliant, ETL listed to UL508.
SPECIFICATIONS: All specifications meet or exceed DMX512 requirements
SPECIFICATIONS: All specifications meet or exceed DMX512 requirements
Input circuit: Protected EIA-485 receiver (LT1785). Transient protected to 15 KV, Continuous to 60 V.
Input signal: 0.2 volts minimum, 12 volts maximum, DMX512, DMX512/1990, or DMX512-A.
Signal Connectors: Phoenix Contact Combi-Con Pluggable terminal blocks. Two provided: In and Through.
Termination: Removable 120 Ohm termination provided on feed through.
Power Input: 120 VAC 60 Hz 16 Amps at full load (Uses 20 Amp branch circuit at 80% capacity). Actual current draw is connected load plus 50 mA (max).
Idle Power: Less than 1 Watt.
Input Power Connector: Three position screw terminal block accepts up to 12 AWG solid or stranded wire (Line, Neutral, Ground).
Power Output: 120 VAC 60 Hz 250 Watts per output.
Output Protection: 2 Amp self-resetting over current device on output, 100 Ohm PTC thermistor on driver.
Output Connectors: One three position screw terminal block per output accepts up to 12 AWG solid or stranded wire (Line, Neutral, Ground).
Dimming Circuit: Digitally fired, phase controlled 16 Amp snubberless triac (Alternistor) with high dv/dt driver. Triacs are screwdriver replaceable. One spare triac provided. A leakage control circuit on each output prevents ghosting of moderate loads. This dimmer is forward phase firing (aka: leading edge firing).
Rise Time: 12 uS (10% to 90% at 90 degree firing angle) at rated load.
Dimming Curve: Square law.
Non-dim Curve: Outputs set to non-dim turn on and off at 1%. Outputs switch at zero crossing.
DMX Footprint: Eight consecutive DMX slots beginning with the selected DMX Starting Address.
DMX Starting Address: Nine position internal DIP switch. Must be set at time of install. Not user accessible.
Non Dim Switch: Nine position internal DIP switch. One switch per output plus ‘local’. Not user accessible.
Local Control Switch: When local switch is ON, Non-dim switches function as on/off switches for load testing.
Chase Mode: Factory programmable chase sequence (default is 8-step chase 1/8 seconds per step).
Status Indicators: One multi-function LED:
Blinking Red Power on, no input signal
Solid Red Local control mode enabled
Blinking Green DMX input signal present
Solid Green DMX input present, output 1 above 0
Cooling: Maintenance free convection with front panel ventilation. No fan.
Isolation: Double isolated: DMX512 input is isolated from control electronics to 1500 Volts. Control electronics are isolated from AC power circuits to 600 Volts.
Color: Gray rear and sides, Green cover.
Knock-outs: Ten provided (five on each side). Each knock-out accepts two fitting sizes. There are two each of 0.75" / 1.00" and 0.50" / 0.75" and one of 1.00" / 1.25"
Safety listing: ETL listed to UL 508
Size and Weight: 12"H × 4"D × 12"W, 10 Pounds
Warranty: Five-year parts and labor warranty against manufacturing defects.
Warranty: Five-year parts and labor warranty against manufacturing defects.
Call to order